Difference between revisions of "Scoring Functions"

From Rizzo_Lab
Jump to: navigation, search
(Continuous Score/DOCK Cartesian Energy)
Line 69: Line 69:
 
| no
 
| no
 
|-
 
|-
continuous_score_secondary Does the user want to perform continuous non-grid scoring as the secondary scoring function? no
+
|continuous_score_secondary
cont_score_rec_filename File that contains receptor coordinates receptor.mol2
+
| Does the user want to perform continuous non-grid scoring as the secondary scoring function?
cont_score_att_exp VDW Lennard-Jones potential attractive exponent 6
+
|no
cont_score_rep_exp VDW Lennard-Jones potential repulsive exponent 12
+
|-
cont_score_rep_rad_scale Scalar multiplier of the radii for the repulsive portion of the vdw energy component only 1.0
+
|cont_score_rec_filename
cont_score_use_dist_dep_dielectric Distance dependent dielectric switch yes
+
|File that contains receptor coordinates
cont_score_dielectric Dielectric constant for the electrostatic term
+
|receptor.mol2
 +
|-
 +
|cont_score_att_exp
 +
|VDW Lennard-Jones potential attractive exponent
 +
|6
 +
|-
 +
|cont_score_rep_exp
 +
|VDW Lennard-Jones potential repulsive exponent
 +
|12
 +
|-
 +
|cont_score_rep_rad_scale
 +
|Scalar multiplier of the radii for the repulsive portion of the vdw energy component only
 +
|1.0
 +
|-
 +
|cont_score_use_dist_dep_dielectric
 +
|Distance dependent dielectric switch
 +
|yes
 +
|-
 +
|cont_score_dielectric
 +
|Dielectric constant for the electrostatic term
 +
|
 +
|-
 
cont_score_vdw_scale Scalar multiplier of vdw energy component 1
 
cont_score_vdw_scale Scalar multiplier of vdw energy component 1
 
cont_score_vdw_scale Flag to turn off vdw portion of the scoring function when cont_score_vdw_scale=0 yes
 
cont_score_vdw_scale Flag to turn off vdw portion of the scoring function when cont_score_vdw_scale=0 yes
 
cont_score_es_scale Scalar multiplier of electrostatic energy component 1.0
 
cont_score_es_scale Scalar multiplier of electrostatic energy component 1.0
 
cont_score_turn_off_es Flag to turn off es portion of the scoring function when cont_score_es_scale = 0 yes
 
cont_score_turn_off_es Flag to turn off es portion of the scoring function when cont_score_es_scale = 0 yes
 +
|}

Revision as of 12:45, 14 April 2020

DOCK uses several types of scoring functions to discriminate among orientations and molecules. Scoring is requested using the score_molecules parameter. A large portion of scoring functions can be called through descriptor score (but not all). Those with descriptor score functionality will be denoted as such.

Grid-Based Score

DOCK needs a fast scoring function to evaluate poses rapidly during growth. The energy grid is used for this. The grid stores the non-bonded Molecular Mechanics Potential of the receptor at each grid point.

Mm-equation.png

Grid can be called under descriptor score but it is suggested to not mix grid-based and cartesian space as that will dramatically increase computing time.

Grid Score Parameters

Parameter Description Default Value
grid_score_primary Does the user want to perform grid-based energy scoring as the primary scoring function? yes-
grid_score_rep_rad_scale Scalar multiplier of the radii for the repulsive portion of the VDW energy component only when grid score is turned on 1.0
grid_score_vdw_scale Scalar multiplier of the VDW energy component 1
grid_score_turn_off_vdw A flag to turn off vdw portion of scoring function when grid score vdw scale = 0 yes
grid_score_es_scale Flag to scale up or down the es portion of the scoring function when es scale is turned on 1
grid_score_turn_off_es A flag to turn off es portion of scoring function when grid score es scale = 0 yes
grid_score_grid_prefix The prefix to the grid files containing the desired nrg/bmp grid grid

Grid Score Output Components

These values will be printed in the header of the mol2 file post DOCK process.

Output Component Description
Grid_score Sum of the VDW and ES interactions
Grid_vdw_energy VDW interaction between the ligand grid
Grid_es_energy ES interaction betweent eh ligand and grid

Continuous Score/DOCK Cartesian Energy

Continuous scoring may be used to evaluate a ligand:receptor complex without the investment of a grid calculation, or to perform a more detailed calculation without the numerical approximation of the grid. Continuous score is implemented under Descriptor Score as well. Continuous score is a cartesian based score and can be combined with other Cartesian based scores with very little computational expense.

cont_score_vdw_scale Scalar multiplier of vdw energy component 1 cont_score_vdw_scale Flag to turn off vdw portion of the scoring function when cont_score_vdw_scale=0 yes cont_score_es_scale Scalar multiplier of electrostatic energy component 1.0 cont_score_turn_off_es Flag to turn off es portion of the scoring function when cont_score_es_scale = 0 yes
Parameter Description Default Value
continuous_score_primary Does the user want to perform continuous non-grid scoring as the primary scoring function? no
continuous_score_secondary Does the user want to perform continuous non-grid scoring as the secondary scoring function? no
cont_score_rec_filename File that contains receptor coordinates receptor.mol2
cont_score_att_exp VDW Lennard-Jones potential attractive exponent 6
cont_score_rep_exp VDW Lennard-Jones potential repulsive exponent 12
cont_score_rep_rad_scale Scalar multiplier of the radii for the repulsive portion of the vdw energy component only 1.0
cont_score_use_dist_dep_dielectric Distance dependent dielectric switch yes
cont_score_dielectric Dielectric constant for the electrostatic term